As mentioned above (2.2.1), the normal PR interval is between 0.12 and 0.20 seconds (120-200 ms). It can be prolonged by a variety of physiologic, pharmacologic and pathologic causes. The PR interval in the ECG shown here is prolonged to 0.28 seconds. This indicates conduction slowing somewhere within the AV junction.